Data Centers, Laboratories, Electrical panel rooms,
For your sensitive areas that require heat and humidity control
We produce Precision Controlled Air Conditioning Hvac solutions
Precision controlled air conditioning DX,Free Cooling,Adiabatic,
Direct and Indirect Free Cooling Systems
Panel Type Air Conditioning Systems
Air Handling Units (AHU)
Periodic maintenance and 24/7 service
BMS automation systems
Mechanical project management and technical consultancy services
Raised floor applications
Gas fire extinguishing systems
Air sampling systems
Hot steam and ultrasonic type air humidification systems
Precision Controlled Air Conditioning systems
.png)
_edited.jpg)


.png)
Precision Controlled Air Conditioners:
Precision Controlled Air Conditioning Devices are designed for the air conditioning of computer rooms, computer centers, telecommunication areas, highly automated offices, central offices, conference halls, museums, libraries, laboratories and similar volumes where temperature and humidity rates must be kept constant with very low tolerances.
With the developed special microprocessor, the cooling, heating, humidification, dehumidification and filtration functions of the devices are controlled and the desired environmental conditions are achieved.
Precisely controlled devices can operate 24 hours a day, 365 days a week to ensure the necessary temperature, humidity and cleaning conditions.
Precision Controlled Air Conditioning Systems are used in areas where high precision in temperature and humidity values is required.
With Precision Controlled Air Conditioning devices designed to operate 365 days and 24 hours a year, the temperature, humidity, air flow and cleanliness conditions required for the environment are provided at the best level, thus maximizing the life and efficiency of the electronic equipment operating in the environment.

Periodic maintenance and 24/7 service


Sensitive Air Conditioner 24/7 Uninterrupted Service
If a problem occurs in the functions of sensitive air conditioners, whose entire purpose is to maintain the desired temperature values uninterruptedly for 24 hours, immediate repairs must be made.
Otherwise, you may be faced with situations that may cause serious grievance.
That's why precision air conditioning services are offered uninterruptedly, 24 hours a day, every day of the week.
In this way, professional technical services can be used for sensitive air conditioners in case of any technical malfunction, regardless of the time of day.
With quick interventions, it is possible to start maintaining ideal temperature values again without any damage to the product, system or elements.
Precisely Controlled Air Conditioning Periodic Maintenance
As with all air conditioning devices or systems, periodic maintenance is very important in sensitively controlled air conditioning models.
Precise air conditioning periodic maintenance is very important to prevent technical malfunctions from occurring at the most unlikely times, to avoid high costs due to technical malfunctions, and to ensure highly efficient use.
With regular, sensitive air conditioning maintenance at least twice a year, it is possible to prevent possible malfunctions of the devices and ensure that their performance is always at the same quality as the first day.
However, as with repair interventions, it is very important that periodic maintenance operations are carried out only by a specialist.
The precision air conditioning service, which effectively monitors the periodic precision air conditioning maintenance schedule on behalf of the consumer, offers professional answers to the needs in this regard.
What Checks Are Made During Maintenance?
Electrical measurements and controls
Engines, Compressors, Fan motors controls
Thermal investigations (Optional)
Air filter controls
Strainer controls
Condensate drain drain checks
Refrigerant gas controls
Belt pulley controls
Axis misalignment, unbalance measurements
General controls
Reporting
Air Handling Unit (AHU) Cellular Fan and Aspirator
Maintenance and repair

Air Handling Unit Maintenance and Repair
Hygienic air handling units maintenance and repair
Maintenance and repair of comfort air handling units
Maintenance and repair of industrial air handling units
Package type air handling units maintenance and repair
Compact type air conditioners maintenance and repair
Roof top air conditioners maintenance and repair
Precision controlled air conditioners maintenance and repair
Fan coil maintenance and repair
Cell type aspirator and fan maintenance and repair
What Checks Are Made in Air Handling Units and Ventilation Equipment Maintenance?
Maintenance and repair of Air Handling Units Electrical Panels and the power and control elements within the panel
Maintenance and calibration of automatic control elements of Air Handling Units
Maintenance of fan and aspirator electric motors and terminal connection points
Maintenance of fan and aspirator fan bearings and bearings
Maintenance of hot and cold water coils
Damper and silencer controls
Air handling units tightness checks and elimination of leaks
Ventilation ducts tightness checks and leak elimination
Spare parts supply and replacement of coarse and bag filters used in Air Handling Units
Supply and replacement of Hepa and Ulpa Filters, connections and checks of Hepa box, laminar flow units
Controls of Steam Humidifier units
Control and maintenance of field control elements (thermostats, differential pressure sensors, 3 or 2-way valves and motors, damper motors, flow adjustment units such as vav, cav, frequency converters)
Checking the tension of fan and aspirator belts and any damage that may occur due to operating time, and replacing them if necessary.
Maintenance and control of PLC controlled systems
Control of computer software

BMS Automation Integrations




Heating-Cooling-Ventilation (Mechanical Automation) Systems
Depending on the business's field of activity, comfort-control needs and electro-mechanical systems, the most effective use of resources, reporting, minimizing the human factor in mechanical system controls such as heating, cooling, ventilation and water supply, saving operating costs and providing full control are the basic principles. is the purpose.
What systems do we control?
Air Handling Units (AHU)
Exhaust and fresh air fans
circulation pumps
Fan and pump frequency inverter devices
Boilers and heating systems
Precisely controlled air conditioning systems
Chillers and cooling systems
Room mechanical equipment (Fan Coil, VRV, VAV, split air conditioner…)
Water storage and supply systems, water purification, packaged devices
Temperature-humidity-pressure sensors and switches
Air-water flow rate, speed sensors and switches
CO2, Air quality sensors
Water-gas-CO leak detectors
Motorized proportional, on/off, floating control valve motors and valve bodies
Butterfly, solenoid valves
Proportional-on/off- floating control damper motors
Fully programmed controllers with and without display
Mechanical - Room and FCU thermostats with LCD Display
FCU thermally actuated and motorized valves
WEB-based controllers
Graphic, animated central monitoring-control and reporting software
LON, Bacnet etc. open protocol system integration
Package system integration with RS232 output (Chiller, compressor, generator, etc.)
Technical Consultancy and Application


Technical Consultancy
During the project planning and implementation stages; Providing all the technical support needed in plumbing, fire installation, compressed air installation, HVAC (heating-cooling-air conditioning-ventilation installation). It ensures that mechanical installation and their automation systems projects are carried out in accordance with the relevant standards and regulations.
APPLICATION
Projected systems; Checking compliance with engineering ethics, technical specifications and the most current relevant regulations
Conducting cost analysis of projects in terms of energy efficiency and environment
Ensuring that necessary technical meetings are held
Selection of materials in accordance with project goals
Follow-up of the construction site work program and checking its compliance with the project
Identifying deficiencies and making provisional acceptances
Making final acceptance
Gas Extinguishing and Air Sampling Systems


Gas Extinguishing Systems
Gas extinguishing systems extinguish the fire by lowering the temperature and reducing the amount of oxygen in the environment below the combustion limit.
They have widespread usage areas because they do not harm the places where they are applied, offer flexible usage options, and enable the use of the equipment in the spaces after the extinguishing process.
Clean Gas: It is a volatile liquid or gaseous extinguishing agent that has no electrical conductivity and does not leave waste after evaporation.
In order for a fire to occur, flammable substances must reach a certain temperature and there must be a sufficient amount of oxygen in the environment. For combustion to occur, the oxygen level must not fall below . As the oxygen content drops below 16%, the combustion reaction gradually fades away.
If the oxygen rate drops below 12%, combustion ends.
Gas Extinguishing Systems Usage Areas:
In Uninterruptible Power Supply (UPS) rooms
Computer, server, control rooms
In Turbines (Hep, Thermal Power Plant, Wind Turbines)
In transformers
In electrical distribution panel rooms
In generators, compressors, ventilation units,
In Cable Galleries
At natural gas distribution stations
Floating and fixed platforms
It is widely used on ships.
IT rooms and centers
Main command and control centers
automation centers
Art galleries, archives and museums
Libraries
Laboratories and research and development centers
telephone switchboards
Medical supply warehouses
Raised Floor Systems
Raised Floor
By creating a second floor surface on the reinforced concrete base of the building, it allows the space between the materials such as pipes, cables and ducts belonging to mechanical, electrical and ventilation installations to be quickly delivered to the desired point without the need for any construction work such as demolition or reconstruction, which causes loss of time and money. It is a building material.
We carry out our Raised Floor types, panels, infrastructure systems and raised floor work with our qualified and competent installation personnel.